BinaalineThe construction encyclopedia

Key points

  • Flat-roof membrane types include modified bitumen, single-ply (TPO, PVC, EPDM), spray foam and liquid-applied systems.
  • SBS modified bitumen is more flexible; APP is less flexible and usually torch-applied.
  • PVC and TPO seams are heat-welded with hot air; EPDM seams are bonded with adhesives or tapes.
  • In an inverted roof, XPS insulation sits above the membrane and protects it from UV, temperature extremes and mechanical damage.
Written for:OwnerContractorSupplier

Roof waterproofing is the first line of defence against rain, washing water and AC condensate. Any mistake shows up later as stains, damp and rust in the roof slab reinforcement. See rebar corrosion.

1) Membrane types compared

Types of flat and low-slope roof membranes include polymer-modified bitumen, single-ply thermoplastic or thermoset membranes, spray polyurethane foam and liquid-applied systems1:

TypeDescriptionNotes
SBS modified bitumenRubber-modified bitumen layers with reinforcementMore flexible once installed; applied with hot asphalt or self-adhesive backing1.
APP modified bitumenPlastic-modified bitumenLess flexible than SBS, applied by heating the underside with a torch; the source cites a life of up to 20 years for modified bitumen roofs in general (SBS and APP)1.
TPOSingle-ply manufactured in white, with hot-air welded seamsRelatively new; formulations have improved since the early 2000s1.
PVCSingle-ply with hot-air welded seamsResistant to root penetration, so suitable under green roofs1.
EPDMThermoset rubber membraneCannot be heat-welded; seams are bonded with adhesives or special tapes1.
Liquid-appliedBrushed or sprayed to form a continuous membraneMostly used to repair or recoat existing roofs, and many can be applied over other systems; also suited to complicated shapes, details and penetrations1.
Spray polyurethane foam (SPF)Sprayed polyurethane giving thermal insulation and waterproofing togetherVery light; the source cites 20–30 years with maintenance, and it needs regular inspection and re-coating of the protective layer1.

2) Where does the insulation go? The "inverted roof"

In a conventional roof the insulation sits under the membrane, leaving the membrane exposed to the sun. In an inverted roof (protected membrane roof) the membrane is laid directly on the slab, then extruded polystyrene (XPS) boards above it, then a protection layer (pavers or gravel). In this arrangement the insulation protects the membrane from mechanical damage during and after construction, from temperature extremes, and from ultraviolet radiation that causes premature failure2.

Why XPS specifically? Because in an inverted roof the insulation sits above the membrane and is exposed to water, so it must be a type that doesn't absorb water and keeps its performance, which the manufacturer states for XPS boards2. For comparing insulation materials see thermal insulation and roof insulation.

3) The details that usually fail

Common practical observations from inspecting roof leaks.

  • Upstands at walls: turning the membrane up the wall, fixing its top edge and protecting it.
  • Around drains: reinforcing the membrane and connecting it to the drain with a dedicated piece.
  • Pipe penetrations and supports for AC units and tanks: any hole made after waterproofing must be treated with the same system.
  • Falls: ponding water accelerates membrane deterioration. Ask for clear falls to the drains.

4) Flood test before covering

A common supervision practice: after waterproofing and before protection and tiles, the drains are plugged and the roof is flooded for a period set by the supervisor, while the ceiling below is watched. Any leak is fixed before covering, because finding it later is expensive.

5) Summary of pros and cons

Bitumen membranes

  • Proven, widespread, and installers are easy to find.
  • Good tolerance of movement with SBS.
  • Torching needs fire precautions and is not suitable over timber1.

Single-ply and liquid-applied

  • TPO/PVC come in white or light colours with welded seams.
  • Liquid systems are self-levelling and excellent for details.
  • Weld quality or applied thickness depends entirely on the installer's skill.

Sources

The number next to a statement points to its source in this list. Sources back the general information; anything marked “practical advice” is editorial experience, not a quoted source. Anything that affects safety, structural design or electrical installations needs a licensed professional, and in Saudi Arabia the binding reference is the Saudi Building Code.

  1. 1Types of Roof Membranes for Flat or Low-Slope Roofs — Archtoolbox
  2. 25 Reasons to Choose an Inverted Roof (Protected Membrane Roof with XPS) — DuPont Performance Building Solutions
Was this guide useful?
This guide is for general information and planning, based on standards and technical guides. Standards are revised periodically; in Saudi Arabia the binding reference is the Saudi Building Code and the instructions of the competent authorities. For design and execution, use a licensed engineer or technician. Found an error? Tell us.