BinaalineThe construction encyclopedia

Key points

  • Duct losses can exceed 30% of heating and cooling energy when ducts run through unconditioned space (such as above an uninsulated roof).
  • Splits allow room-by-room control, but their washable mesh filters capture little and need cleaning about every two weeks.
  • Connecting more than 3 indoor units to one outdoor unit is generally not recommended in multi-zone systems.
  • An oversized unit short-cycles, wasting energy without controlling temperature and humidity; size each space to its load.
Written for:OwnerContractor

The choice of AC type affects the electricity bill, comfort and maintenance for many years. This guide compares the common home systems and complements the AC and efficiency label guide.

1) The basic difference

  • Ducted (central or concealed): one centrally located air handler blows conditioned air through a duct system1.
  • Ductless split: small indoor units installed in the rooms themselves1.
  • Single or multi-zone: one outdoor unit for one indoor unit, or several; the source says more than 3 indoor units on one outdoor unit is generally not recommended1.
  • Short-run ducted: a concealed unit with short ducts serving several nearby rooms1.

2) Comparison

ItemDuctless splitCentral or ducted
Distribution lossesNo ducts, so no duct losses1Duct losses can exceed 30% of heating and cooling energy in unconditioned space1
ControlEach unit runs independently at its own temperature1Depends on the zoning in the design
FiltrationMany have washable mesh filters with poor filtration1A higher-MERV filter can be fitted depending on the system. See indoor air and dust
DehumidificationSome newer high-efficiency units dehumidify less well1Depends on the design
SpaceNo bulky ducts; convenient for retrofits1Needs room for ducts and the air handler (false ceilings)
AppearanceUnits visible in roomsHidden; only grilles show
If you choose ducts: keep them inside the conditioned space or insulate and seal them well; ducts above a sun-exposed roof without enough insulation waste much of the cooling. See roof insulation and sun protection.

3) Size: bigger is not better

Sizing the outdoor unit and each indoor unit to the space load is imperative; an oversized unit short-cycles, wasting energy without proper temperature or humidity control1. Ask a technician or engineer for a load calculation instead of a "one ton per room" rule (practical advice).

What goes into a load calculation, and what to prepare

We give no per-square-metre figure because the load varies a lot between homes. A proper calculation combines these factors for each room:

FactorWhy it changes the resultWhat to prepare
Area and heightThe volume of air to coolThe drawing or measurements
Orientation and sunWest- and south-facing rooms gain more heatThe orientation of each wall and window. See Sun protection
WindowsTheir area, glass type and shadingWindow sizes and glass type. See Windows
InsulationUninsulated walls and roofs let more heat inWhether the roof and walls are insulated, and with what. See Thermal insulation
People, appliances and lightingEach adds heat inside the roomHow the room is used (majlis, kitchen, bedroom) and the usual number of people
Air leakage and ventilationHot air coming in needs coolingHow well doors and windows seal
City climateDesign temperature and humidity differ between citiesThe city name

Ask for the calculation in writing for each room and keep it with the house drawings; it helps when replacing units later.

4) Maintenance

  • Split mesh filters: clean about every two weeks1, more on dusty days.
  • Deep cleaning of indoor units (blower and coil): every 1 to 3 years depending on use, with a technician's equipment1.
  • Condensate line and pan: make sure both are installed correctly. The design of most wall-mounted units lets moisture collect on the blower wheel in cooling mode, so dust and mold build up on it1. See AC problems.

5) Before buying

  1. Compare the Saudi energy efficiency label of the specific model, not the brand name. See the AC guide.
  2. Ask for a load calculation for each space.
  3. For ducted systems: where will the ducts run, and how will they be insulated and sealed?
  4. For splits: where does the condensate drain? See water around the building.
  5. In very dry places and for large open spaces, an evaporative cooler may be a complementary option.

Sources

The number next to a statement points to its source in this list. Sources back the general information; anything marked “practical advice” is editorial experience, not a quoted source. Anything that affects safety, structural design or electrical installations needs a licensed professional, and in Saudi Arabia the binding reference is the Saudi Building Code.

  1. 1Ductless (Mini-Split) Heat Pumps (Building America Solution Center) — Pacific Northwest National Laboratory / U.S. DOE
Was this guide useful?
This guide is for general information and planning, based on standards and technical guides. Standards are revised periodically; in Saudi Arabia the binding reference is the Saudi Building Code and the instructions of the competent authorities. For design and execution, use a licensed engineer or technician. Found an error? Tell us.