  • IEC 60445: line conductors black, brown or grey (in the UK L1 brown, L2 black, L3 grey); neutral blue; protective earth green/yellow.
  • Green-and-yellow is the only combination recognised for the protective conductor and is used only for the purposes the standard specifies.
  • A typical socket circuit is 16 A with 1.5 or 2.5 mm² cable depending on length and heat, plus a dedicated circuit for each large appliance; actual cable size is set by design.
  • Cable size depends on the load, the breaker, cable length (voltage drop), installation method and ambient temperature.
Written for:OwnerContractorSupplier

Knowing wire colours isn't only for electricians; it helps you understand what you see when removing a socket or light fitting, and spot non-compliant wiring.

1) Colours under IEC 60445

The international standard IEC 60445 (7th edition, 2021) sets the conductor identification colours: neutral blue, AC line conductors black, brown or grey with no preferred order, and the protective conductor green-and-yellow1. The table below is the allocation used in the UK according to the IET table2:

ConductorColour
Phase (L) — in single-phase circuits Brown
Phases in three-phase systems L1 / L2 / L3 Brown / Black / Grey
Neutral (N) Blue
Protective earth (PE) Green/yellow
A fixed rule: green-and-yellow is the only colour combination recognised for the protective conductor and is used only for the purposes the standard specifies; green or yellow is not used in any other two-colour combination1.

The allocation in the table is British, not a Saudi requirement; we could not open the Saudi Electrical Code SBC 401 to check which colours it adopts, so ask the design engineer. In older homes you may find other colours (such as red or black for phase). Don't assume a wire's function from its colour in old wiring; it must be tested with instruments by a technician.

2) Circuit division and cable sizes

Sizes are measured in square millimetres (mm²) of copper. Schneider Electric's electrical installation guide summarises what national standards typically recommend for dividing circuits in a dwelling3:

CircuitRecommendation
LightingAt least one lighting circuit, each circuit supplying several rooms of no more than 50 m² in total.
SocketsAt least one 16 A socket circuit (per the national socket system), with a reasonable number of sockets, taking into account the cable size used (1.5 or 2.5 mm²), cable lengths (voltage drop) and temperature rise at connections.
Large loadsA dedicated circuit for each large appliance such as washing machine, dishwasher and cooker. Water heaters and fixed heaters are connected through fixed terminals, not a plug.

The guide adds that phase, neutral and earth conductors in a circuit should be the same size up to 32 A circuits3.

How many sockets and lighting points per room?

An example of recommended minimums in dwellings, from the same guide3:

RoomMinimum fixed lighting pointsMinimum 10/16 A sockets
Living room15
Bedroom, lounge, dining13
Kitchen24 (above the worktop, plus dedicated circuits)
Bathroom21
Entrance, corridors, stairs11
Storeroom11
Laundry12

This is an indicative minimum from an international reference. Actual design and socket positions in bathrooms are governed by zone requirements and the Saudi code SBC 401.

3) Why is there no size that "fits everything"?

Choosing the correct cable size is an engineering process under IEC 60364-5-52 and the local code, depending on:

  1. The load current and the breaker protecting the circuit (the breaker must protect the cable).
  2. Circuit length: the longer the cable, the greater the voltage drop, and a larger size may be needed.
  3. Installation method: in conduit in the wall, surface, buried, or grouped with other cables in the same conduit.
  4. Ambient temperature: in sun-exposed roofs temperature rises, reducing the cable's current capacity.

The installation guide confirms this: conductor size and protective device rating depend on the loads, location temperature, the construction material the cables pass through, installation method, and the influence of neighbouring circuits3.

4) Voltage, phases and the main cable

  • Voltage: a Council of Ministers resolution changes the voltage system in residential and commercial units from 127/220 V to 230/400 V4. Details in Voltage and plugs.
  • Single or three phase: a three-phase supply brings three phases and a neutral (colours in Section 1). The meter type and capacity are set by the utility based on the approved loads in the design, not by the owner alone.
  • Spreading circuits across phases: the designer balances the load; adding ACs or heaters later on one phase can trip the breaker or cause heating. Any large addition should be reviewed with a qualified electrician.
  • Wire vs cable: a wire is one insulated conductor run inside conduit; a cable is several conductors in one sheath (such as the main cable from the meter to the consumer unit). The main cable size is part of the design, not a site guess.
  • Where do concealed cables run? The well-known British rule: vertically or horizontally in line with an accessory, or within set zones near wall corners; otherwise cables need other protection5. Ask for the drawing before drilling into a wall.

This section is for understanding and requesting the right documents, not for working on live electricity. See Breakers and the electrical path and Earthing.

5) When buying cable

  1. Check the real cross-section; some counterfeit products are smaller than stated.
  2. Buy cable complying with approved standards, from reliable sources.
  3. Stick to the standard colours to ease maintenance and protect whoever works after you.
  4. Ask for the circuit schedule (which breaker feeds which points) and keep it.
Warning: the figures above are for general understanding, not design. Design and installation are the responsibility of a qualified engineer/technician under the Saudi Electrical Code SBC 4016.

Sources

The number next to a statement points to its source in this list. Sources back the general information; anything marked “practical advice” is editorial experience, not a quoted source. Anything that affects safety, structural design or electrical installations needs a licensed professional, and in Saudi Arabia the binding reference is the Saudi Building Code.

  1. 1IEC 60445:2021 — Identification of equipment terminals, conductor terminations and conductors (official preview pages: clauses 6.2 and 6.3.2) — International Electrotechnical Commission (IEC) — preview published by iTeh Standards, 2021-07
  2. 2Harmonised colours and alphanumeric marking — IEE (now IET) — Wiring Matters, Paul Cook, 2004
  3. 3Residential electrical installation — Circuits — Electrical Installation Guide (Schneider Electric)
  4. 4Unified plugs and sockets campaign — SASO 2203 and the move to 230/400 V — Saudi Standards, Metrology and Quality Organization (SASO)
  5. 5Zones for Concealed Cables in Walls — BS 7671 Wiring Regulations — Flameport
  6. 6Saudi Electrical Code SBC 401 — code requirements (based on IEC 60364 with local amendments) — Saudi Building Code National Committee
Was this guide useful?
This guide is for general information and planning, based on standards and technical guides. Standards are revised periodically; in Saudi Arabia the binding reference is the Saudi Building Code and the instructions of the competent authorities. For design and execution, use a licensed engineer or technician. Found an error? Tell us.